We completed an electric shower replacement in Slough, swapping a failing unit for a new one on the existing water feed and electrical supply. A like-for-like job usually takes two to four hours, provided the existing cable and protective device suit the new shower. If they don’t, the job grows, and checking that is the […]

We completed an electric shower replacement in Slough, swapping a failing unit for a new one on the existing water feed and electrical supply. A like-for-like job usually takes two to four hours, provided the existing cable and protective device suit the new shower. If they don’t, the job grows, and checking that is the most important part of the visit.

Why electric showers stop working

An electric shower heats cold mains water as it passes over an internal element. The usual faults are:

  • Limescale. The Thames Valley is generally a hard water area, and scale on the element and shower head cuts heat output and flow.
  • A failed element or thermal cut-out. The shower runs but stays cold or lukewarm.
  • Leaks. Water inside the casing is a safety problem as well as a plumbing one.
  • A tripping RCD or MCB. This can signal a fault or water ingress. Switch the shower off at the isolator until it has been checked.
  • Low flow or unstable temperature. Often a blocked inlet filter or low mains pressure rather than the unit itself.

Repair or replace? Descaling the head and filter is worth trying when reduced flow is the only problem. We recommend replacement when the element has failed on an older unit, the casing is cracked or leaking, the RCD keeps tripping, or the owner wants a higher-powered or thermostatic model. That is professional judgement, not a regulation.

Who is allowed to fit an electric shower?

An electric shower is a high-load appliance. It should sit on its own circuit from the consumer unit, with a suitably rated MCB and RCD protection, and a double-pole isolator (usually a ceiling pull-cord) outside the shower zones. The cable must be large enough for the shower’s rating, and higher-rated showers need heavier cable. The manufacturer’s instructions and BS 7671, the UK wiring regulations, set the exact requirement.

  • Like-for-like swap on a suitable existing circuit: generally minor electrical work, which the installer should test and certify, typically with a Minor Electrical Installation Works Certificate.
  • Higher rating, or no existing circuit: the cable, protective device and consumer unit all need checking, and a new circuit is notifiable under Part P of the Building Regulations in England.
  • The water side: a mains cold feed with an isolation valve.

This is not a DIY electrical job. Water and mains electricity in the same room leave little margin for error.

How the replacement was done

  1. Check the existing installation. Rating, cable, protective device, water feed and wall condition. A swap is only like-for-like if the new unit suits the existing circuit.
  2. Isolate the electrics. Switch off at the isolator and the consumer unit, then prove the supply dead with a tester.
  3. Isolate the water. Close the isolation valve, or the stopcock if there isn’t one, and fit a valve as part of the job.
  4. Remove the old unit. Disconnect the cable and water inlet, drain residual water and take the unit off the wall.
  5. Inspect. Look for heat damage at the cable and terminals, check the fixings and clean off limescale.
  6. Mount and connect the new shower. Fix the unit, connect the inlet through the isolation valve and wire it to the manufacturer’s instructions, checking cable entry and seals.
  7. Test the water first. Check for leaks and flush the line before power goes back on.
  8. Test the electrics and the shower. Complete and record the electrical tests, then run the shower at full power to check flow, heating, cut-out and RCD operation.
  9. Hand over. Give the customer the certificate, the manual and a quick guide to the controls.

Choosing a replacement electric shower

FactorWhat to checkWhy it matters
kW ratingCommonly about 7.5 kW to over 10 kWHigher output heats better in winter but needs heavier cable and a bigger protective device
Existing circuitCable size, MCB, RCDThe new shower must suit what is already in the wall
Mains pressureManufacturer’s minimumElectric showers run on mains cold water and struggle on low pressure
Thermostatic controlHolds temperature steadyMore comfortable, and safer for children and older users
FootprintMatches old fixings and inlet positionAvoids new holes and re-tiling

Electric showers need a mains cold feed. A bathroom supplied only from a loft tank is generally not suitable without a separate mains pipe.

Running cost example: a 9.5 kW shower used for 8 minutes draws about 1.27 kWh (9.5 x 8 / 60). Multiply that by your own unit rate to see the cost per shower. A shorter shower saves more than a lower-rated unit, which simply gives a cooler one.

How much does electric shower replacement cost?

Published 2026 UK price guides give a broad picture for a like-for-like swap:

  • Labour alone is commonly quoted at roughly £100 to £300.
  • Installed cost including the unit is typically about £250 to £600.
  • Units start around £100 for budget models, roughly £150 to £250 mid-range, and £300 or more for premium.
  • London and South East rates tend to sit at the higher end.

The price rises when a new circuit or heavier cable is needed, when the new shower has a higher rating than the old one, when an isolation valve or pipework has to be added, or when the wall needs repair.

Common mistakes

  • Assuming “like-for-like” without checking the circuit. A higher-rated shower on an undersized cable is a fire risk.
  • Buying the unit before checking rating, pressure and cable.
  • Reusing heat-damaged cable ends or terminals.
  • Skipping the isolation valve. Every future repair becomes harder.
  • No proper double-pole isolator.
  • No test and no certificate. You need the paperwork for insurance and any future sale.
  • Ignoring limescale. A new shower in a hard water area will scale up too.

Tips from the job: photograph the old wiring and pipework before disconnecting anything; check the cable insulation at the terminals for discolouration; descale or replace the shower head every year or two; and run the shower at full power for several minutes at the end, because some faults only show under sustained load.

Slough homes: what to expect

Slough has a mix of 1930s semis in areas such as Cippenham and Langley, post-war housing in Britwell and Chalvey, and newer flats around the town centre. Older homes may have original wiring, a small consumer unit or a shower circuit added decades later, and these need closer checking. Flats can have restricted access and a different water pressure from a house. Hard water makes limescale a common cause of failure across the area.

When to call a professional

Call one if the shower is leaking, trips the RCD or smells of burning (switch it off at the isolator and consumer unit first), if you want a higher-rated unit, if you don’t know the age or rating of the cable, or if you need a certificate for insurance, a landlord’s records or a sale. Our plumbing services covers the work OnTime Plumbers does.

Frequently asked questions

Can I replace an electric shower myself? The water connection may be within a competent DIYer’s reach, but the electrical connection should be made and certified by a qualified person.

How long does it take? Typically two to four hours for a like-for-like swap, longer if the circuit needs checking or upgrading.

How much does it cost in Slough? UK guides put a like-for-like swap at roughly £250 to £600 installed, with labour alone from about £100 to £300.

Can I fit a higher kW shower than my old one? Only if the existing cable, protective device and consumer unit can safely support it. Otherwise the circuit must be upgraded.

Why is my electric shower only lukewarm? Usually limescale on the element or head, a failing element, or cold incoming water in winter.

Does it need Building Regulations approval? A like-for-like replacement on a suitable existing circuit is generally minor work. A new circuit is notifiable under Part P in England. Confirm with your installer.

Is it safe to use a shower that trips the RCD? No. Isolate it and have it checked first.

Need an electric shower replaced in Slough?

OnTime Plumbers replaces electric showers, from straightforward like-for-like swaps to upgrades that need circuit checks. Tell us the make and rating of your current shower and what you want to replace it with, and we’ll confirm the job and the price before we start.